Product BrochureProduct Details:| Minimum Order Quantity | 1 Piece |
| Measuring Range | 0 to 1300 um |
| Brand | Accuplus |
| Accuracy | 3 % of reading |
| Resolution | 1 um |
| Minimum Measurement Area | 6 mm |
| Display Type | Digital |
| Model Name / Number | DFT-222 |
| Power Supply | 2 X 1.5 AAA batteries |
| Weight | Up to 92 g |
| Storage Temperature | -20 to 70 Degree |
| Dimension | 110x53x24 mm |
| Operation Temperature | 0 to 40 Degree |
| Type | F / NF |
Feature
1. 128*128 dot matrix LCD display, standard menu operations;
2. Two measure mode single and continuous;
3. Two group mode direct (DIR) and general(GEN), readings will be lost when power off in direct mode, and not be lost in
general mode. 80 readings can be stored for each group;
4. Zero point calibration and multi-point calibration(up to 4 points) for each group;
5. User can recall, delete specified readings, or delete group readings;
6. Statistics display mean, minimum, maximum and standard deviation;
7. Three probe mode auto, magnetic and eddy current;
8. User can set high or low limit alarm for each group;
9. Power off automatically;
10. USB interface to data transmission;
11. Low battery and error indication;
SPECIFICATIONS
1. Measuring principle Magnetic induction (F-probe) and eddy current (N-probe);
2. Measuring range 0 to 1300um (0 to 51.2mils);
3. Accuracy +- (3% of readings 2um);
+- (3% of readings 0.078mils);
4. Resolution 0um~999um (1um), 1000um~1300um (0.01mm);
0mils~39.39mils (0.01mils), 39.4mils~51.2mils (0.1mils);
5. Calibration One to four point calibration, zero calibration;
6. Data Group One direct group (readings not be stored to memory), four general group (readings can be stored), and each
group have individual statistics, alarm settings and calibration;
7. Statistics No. of readings, mean, minimum, maximum and standard deviation;
8. Units um, mm and mils;
9. Alarm User can set the high/low alarm, and alarm icon displayed on LCD when over the limit;
10. Minimum curvature radius convex 1.5mm(59mils) and concave 25mm(984mils);
11. Minimum measuring size Diameter 6mm(236mils);
12. Minimum thickness of substrate F-probe 0.5mm(0.02"), N-probe 0.3mm(0.012");
13.Computer interface Download data via USB interface;
14. Power supply Two 1.5v AAA battery;
15. Operation temperature 0 to 40(32 to 104);
16. Storage temperature -20 to 70(-4 to 158);
17. Size 110mm*53mm*24mm (4.33"*2.09"*0.94");
18. Weight 92g (3.24oz);
STANDARD CONFIGURATION
Index | Item | Quantity | Note |
1 | Gauge | 1 |
|
2 | Aluminium substrate | 1 |
|
3 | Standard foil | 5 |
|
4 | 1.5V AAA battery | 2 |
|
5 | Technical manual | 1 |
|
6 | USB cable | 1 |
|
7 | Case | 1 |
Additional Information:
Approx. Rs 9,500 / PieceGet Latest Price
Product BrochureProduct Details:| Minimum Order Quantity | 1 Piece |
| Measuring Range | 0 - 1500 um |
| Resolution | 1 um |
| Probe Type | External Probe |
| Display Type | Backlit LCD |
| Minimum Measurement Area | 5 mm |
| Minimum Sample Thickness | 0.4 mm |
| Accuracy | 1 to 3% |
| Model Name/Number | ACCU456B |
| Least Count | 0.1 Micron |
| Data Interface | No Interface |
| Memory | 1000 Readings |
| Power Supply | 2 X 1.5 AAA batteries |
| Power Source | AAA Battery |
| Weight | 80.9g |
| Substrate Type | F And NF |
Additional Information:
Approx. Rs 9,900 / PieceGet Latest Price
Product BrochureProduct Details:| Minimum Order Quantity | 1 Piece |
| Measuring Range | 0 - 2000 um |
| Resolution | 0.1 um |
| Probe Type | External Probe |
| Display Type | Backlit LCD |
| Accuracy | 2% of reading |
| Data Interface | USB + Bluetooth |
| Memory | 1000 Readings |
| Power Supply | 2 x 1.5V AA Batteries |
| Power Source | AA Battery |
| Substrate Type | F And NF |
| Type | F / NF |
Additional Information:
Approx. Rs 7,000 / PieceGet Latest Price
Product BrochureProduct Details:| Minimum Order Quantity | 1 Piece |
| Measuring Range | 0 - 2000 um |
| Resolution | 0.1 um |
| Probe Type | Built In |
| Display Type | Backlit LCD |
| Minimum Measurement Area | 7 mm |
| Accuracy | 1 % of reading |
| Minimum Sample Thickness | 0.2 mm |
| Data Interface | USB |
| Memory | 1000 Readings |
| Power Supply | 2 X 1.5 AAA batteries |
| Power Source | AAA Battery |
| Substrate Type | F And NF |
| Type | F / NF |
Additional Information:
Approx. Rs 11,000 / PieceGet Latest Price
Product BrochureProduct Details:| Minimum Order Quantity | 1 Piece |
| Measuring Range | 0 to 5000 um |
| Probe Type | Interchangeable |
| Display Type | Backlit LCD |
| Accuracy | ±(2 µm+1%) |
| Minimum Sample Thickness | 5 mm |
| Size | 158 X 68 X 34 mm |
| Model Name / Number | ACCU111A |
| Data Interface | USB |
| Brand | Accuplus |
| Power Supply | 2 X 1.5 AAA batteries |
| Power Source | AAA Battery |
| Weight | 170g |
| Operating Environment | -10 to 50 |
| Warranty | 1 year warranty against Mfg. Defects |
| Memory | 2000 |
| Minimum curvature radius convex | 5 mm |
| Substrate Type | F And NF |
| Least Count | 0.1 um |
| Type | F / NF |
| Resolution | 1 um |
Additional Information:
Approx. Rs 10,500 / PieceGet Latest Price
Product BrochureProduct Details:| Minimum Order Quantity | 1 Piece |
| Measuring Range | 0-3000um |
| Resolution | 0.5 µm |
| Probe Type | External Probe |
| Display Type | Backlit LCD |
| Accuracy | ±1 µm |
| Data Interface | USB |
| Memory | 1000 Readings |
| Power Source | AAA Battery |
| Substrate Type | F And NF |
Approx. Rs 16,850 / PieceGet Latest Price
Product BrochureProduct Details:| Minimum Order Quantity | 1 Piece |
| Substrate Type | F Only |
| Measuring Range | 0-10000um |
| Resolution | 1 µm |
| Probe Type | External Probe |
| Display Type | Backlit LCD |
| Accuracy | ±(1 µm+1%) |
| Data Interface | USB |
| Memory | 1000 Readings |
| Power Source | AAA Battery |
Approx. Rs 5,500 / PieceGet Latest Price
Product BrochureProduct Details:| Minimum Order Quantity | 1 Piece |
| Measuring Range | 0–2000 µm |
| Resolution | 5 µm |
| Probe Type | Built In |
| Display Type | Backlit LCD |
| Accuracy | ±(1 µm+1%) |
| Data Interface | USB |
| Memory | 1000 Readings |
| Power Source | AAA Battery |
| Substrate Type | F And NF |
Approx. Rs 7,000 / PieceGet Latest Price
Product BrochureProduct Details:| Minimum Order Quantity | 1 Piece |
| Measuring Range | 0 - 1500 um |
| Resolution | 0.1 um |
| Minimum Measurement Area | 5 mm |
| Minimum Sample Thickness | 0.4 mm |
| Model Name / Number | Coat F |
| Power Supply | 2 X 1.5 AAA batteries |
Additional Information:
Approx. Rs 17,000 / PieceGet Latest Price
Product BrochureProduct Details:| Minimum Order Quantity | 1 Piece |
| Brand | Samsonic |
| Model Name / Number | FM-12 |
| Measuring Range | 0-12000 um |
| Accuracy | 1.5 % |
| Display Type | Digital |
| Warranty | 1 Year Against Mfg. Defect |
| Packing | Wooden Box |
Taking quality as our prime concern, we are engaged in providing Digital Coating Gauge at industry leading prices.
Features
Additional Information:
Approx. Rs 8,000 / PieceGet Latest Price
Product Details:| Minimum Order Quantity | 1 Piece |
| Brand | Accuplus |
| Type | F |
| Measuring Range | 0 - 1250 um |
| Minimum Measurement Area | 6 mm |
| Display Type | Digital |
| Least Count | 0.1 um |
| Humidity | 95 % |
| Display Digit | 4 |
| Min measuring radius convex | 5 mm |
| Min measuring radius concave | 50 mm |
Approx. Rs 12,990 / PieceGet Latest Price
Product BrochureProduct Details:| Minimum Order Quantity | 1 Piece |
| Brand | Elecoat |
| Model Name / Number | M |
| Type | F |
| Measuring Range | 0 - 2000 um |
| Accuracy | 1 % of reading |
| Resolution | 0.1 um |
| Minimum Measurement Area | 5 mm |
| Power Supply | 9V(6t22) |
Additional Information:
Approx. Rs 1,500 / PieceGet Latest Price
Product BrochureProduct Details:| Minimum Order Quantity | 1 Piece |
| Least Count | 0.01 & 0.001mm |
| Color | White Gray |
| Usage/Application | For Film , Foil Thickness Measure |
| Country of Origin | Made in India |
Explore More Products
© Samruddhi Industries. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited