Product Details:
Minimum Order Quantity | 1 Piece |
Brand | Accuplus |
Model Name/Number | SF-500 |
Accuracy | +/-0.5% |
Humidity | 15% to 80%RH |
Maximum Load | 500N / 50kg / 110Lb |
Minimum Load | 50N / 5kg |
Load Value / Resolution | 0.1N / 0.01kg / 0.01Lb |
Unit | N & kg& Lb |
Power | 3.7V lithium Battery |
Digital force gauge with compact size, high accuracy,easy carry out.Widely applied in electron, high & low voltage electrical appliance, hardware, automobile parts, lighter and ignition system, light industry, mechanical, textile, and so on industries for testing of pull or push load test, insertion force or pull and destructive experiment.
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Model Number/Name | FM-12 |
Display Type | Digital |
Measuring Range | 0-12000 micron |
Brand | Samsonic |
Accuracy | 1.5% |
Packing | Wooden Box |
Warranty | 1 Year Against Mfg. Defect |
Min. Measuring Area | 6 mm |
I Deal In | New Only |
Taking quality as our prime concern, we are engaged in providing Digital Coating Gauge at industry leading prices.
Features
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Model Number/Name | ACCU456 |
Measuring Range | 0-1250 Micron |
Display Type | Digital |
Brand | Accuplus |
Accuracy | 1-2% |
Weight | 99g ( including batteries) |
Resolution | over 100 Micron |
Dimensions | 126 x 69 x 35 mm |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Model Number/Name | Accu-356A |
Measuring Range | 0-1500 Micron |
Material | Ferrous and Non-Ferrous |
Brand | Accuplus |
Accuracy | Up to 3 % |
Weight | 99g |
Least Count | 0.1 micron |
Range | 0-1500 micron |
I Deal In | New Only |
Dimensions | 102 x 66 x 24mm |
Operating Conditions Temperature | Temp 0 - 50 Celsius and Humidity 80% |
Minimum Measurement Area | 5 mm |
Minimum Sample Thickness | 0.3 mm |
Coating Thickness Gauge ACCU356Ais a highly intelligent and precise instrument used to quickly and accurately measure thickness of coating or plating on almost all kind of metal surface.
It not only indicates thickness of coating or plating but also automatically identifies the base material.
It is applicable to measure non-magnetic painting, ceramic, enamel, plastic, rubber coating on magnetic base materials such as iron and steel, non-ferrous metal plating such as nickel & chromium, anticorrosive coating, non-conductive painting, plastic coating and anodic oxide film on non-magnetic conductive devises.
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Model Number/Name | Accu456A |
Material | Ferrous and Non-Ferrous |
Display Type | Digital |
Model | ACCU-456A |
Brand | Accuplus |
Measuring Range | Up to 1500 Micron |
Accuracy | 1-3% |
Weight | 97g |
Least Count | 0.1 micron |
Size | 126 x 69 x 35mm |
Warranty | One year warranty against mfg. defects |
Power Supply | 2x1.5 V |
Bluetooth Interface | Available |
I Deal In | New Only |
Minimum Sample Thickness | 0.3 mm |
Minimum Measurement Area | 5 mm |
Coating Thickness Gauge ACCU456A is a highly intelligent and precise instrument used to quickly and accurately measure thickness of coating or plating on almost all kind of metal surface.
It not only indicates thickness of coating or plating but also automatically identifies the base material.
It is applicable to measure non-magnetic painting, ceramic, enamel, plastic, rubber coating on magnetic base materials such as iron and steel, non-ferrous metal plating such as nickel & chromium, anticorrosive coating, non-conductive painting, plastic coating and anodic oxide film on non-magnetic conductive devises.
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Model | DFT-222 |
Measuring Range | 0 to 2000um |
Type | Ferrous & Non-Ferrous Combine |
Display Type | Digital |
Brand | Accuplus |
Accuracy | 3% of readings 2um |
Weight | Up to 92 g |
Storage Temperature | -20 to 70 Degree |
Power Supply | 1.5 V |
Dimension | 110x53x24 mm |
Operation Temperature | 0 to 40 Degree |
Feature
1. 128*128 dot matrix LCD display, standard menu operations;
2. Two measure mode single and continuous;
3. Two group mode direct (DIR) and general(GEN), readings will be lost when power off in direct mode, and not be lost in
general mode. 80 readings can be stored for each group;
4. Zero point calibration and multi-point calibration(up to 4 points) for each group;
5. User can recall, delete specified readings, or delete group readings;
6. Statistics display mean, minimum, maximum and standard deviation;
7. Three probe mode auto, magnetic and eddy current;
8. User can set high or low limit alarm for each group;
9. Power off automatically;
10. USB interface to data transmission;
11. Low battery and error indication;
SPECIFICATIONS
1. Measuring principle Magnetic induction (F-probe) and eddy current (N-probe);
2. Measuring range 0 to 1300um (0 to 51.2mils);
3. Accuracy +- (3% of readings 2um);
+- (3% of readings 0.078mils);
4. Resolution 0um~999um (1um), 1000um~1300um (0.01mm);
0mils~39.39mils (0.01mils), 39.4mils~51.2mils (0.1mils);
5. Calibration One to four point calibration, zero calibration;
6. Data Group One direct group (readings not be stored to memory), four general group (readings can be stored), and each
group have individual statistics, alarm settings and calibration;
7. Statistics No. of readings, mean, minimum, maximum and standard deviation;
8. Units um, mm and mils;
9. Alarm User can set the high/low alarm, and alarm icon displayed on LCD when over the limit;
10. Minimum curvature radius convex 1.5mm(59mils) and concave 25mm(984mils);
11. Minimum measuring size Diameter 6mm(236mils);
12. Minimum thickness of substrate F-probe 0.5mm(0.02"), N-probe 0.3mm(0.012");
13.Computer interface Download data via USB interface;
14. Power supply Two 1.5v AAA battery;
15. Operation temperature 0 to 40(32 to 104);
16. Storage temperature -20 to 70(-4 to 158);
17. Size 110mm*53mm*24mm (4.33"*2.09"*0.94");
18. Weight 92g (3.24oz);
STANDARD CONFIGURATION
Index | Item | Quantity | Note |
1 | Gauge | 1 |
|
2 | Aluminium substrate | 1 |
|
3 | Standard foil | 5 |
|
4 | 1.5V AAA battery | 2 |
|
5 | Technical manual | 1 |
|
6 | USB cable | 1 |
|
7 | Case | 1 |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Brand | Accuplus |
Display Type | Digital |
Model | Ferrous |
Least Count | 0.1 um |
Measuring Range | Up to 1250 Micron |
Humidity | 95 % |
Minimum Measurement Area | 6 mm |
NF Type Convex | Up to 3 mm |
NF Type Concave | Up to 50 mm |
Display Digit | 4 |
Product Details:
Minimum Order Quantity | 1 Piece |
Model Number/Name | DFT-111 |
Brand | Accuplus |
Measuring Range | 0 to 5000 micron (F) and 0 to 3000 micron (NF) |
Accuracy | 2.5% |
Size | 110 x 53 x 24mm |
Power Supply | 1.5V AAA Battery |
Min. Measuring Area | Diameter 20mm |
Min. Sample Thickness | 0.2mm (F) and 0.2mm (NF) |
I Deal In | New Only |
· 128*128 dot matrix LCD display, standard menu operations.
· Two measure mode: single and continuous.
· Two group mode: direct (DIR) and general (GEN), readings will be lost when power off in direct mode, and not be lost in general mode.80 readings can be stored for each group.
· Zero-point calibration and multi-point calibration (up to 4 points) for each group.
· User can recall, delete specified readings, or delete group readings.
· Statistics display: Mean minimum, maximum and standard deviation.
· Three probe mode: auto, magnetic and eddy current.
· User can set high or low limit alarm for each group.
· Power off automatically
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Model Name/Number | ACCU456B |
Brand | Accuplus |
Measuring Range | 0-1500 Micron |
Material | Plastic |
Accuracy | 1 to 3% |
Weight | 80.9g |
Least Count | 0.1 Micron |
I Deal In | New Only |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Model Name/Number | ACCU111A |
Brand | Accuplus |
Measuring Range | Fe - 0-5000 Micron NFe - 0-3000 Micron |
Material | Plastic |
Accuracy | 2% |
Weight | 170g |
Least Count | 0.1 Micron (100 Micron) 1 Micron(others) |
Warranty | 1 year warranty against Mfg. Defects |
Min. Sample Thickness | 5mm |
Operating Environment | -10 to 50 |
I Deal In | New Only |
Memory | 2000 |
Additional Information: